Instructions for Use and training videos (requires sign-in) Existing customer? Request access
EVIDENCE AND RESEARCH

Tested with clinicians, studied with patients

Usability co-development with three clinical organisations, and registered clinical studies at Amsterdam UMC and in the NHS.

From pre-clinical testing to clinic

  1. Co-developed with clinicians 50 respiratory clinicians and lung function professionals involved in co-developing and proving usability1,2
  2. Pre-clinical verification All three tests verified within acceptance limits; spirometry meets ISO 26782 and ISO 237474
  1. In clinical studies Registered studies at Amsterdam UMC and Central London Community Healthcare NHS Trust3,5
  2. Independent UKCA review Class IIa: a UK Approved Body reviewed electrical safety, EMC, biocompatibility and clinical evaluation.
WORKING WITH
  • Central London Community Healthcare NHS Trust
  • Medisch Spectrum Twente
  • Amsterdam UMC
  • BiosearLab

Summary of pre-clinical performance4

Acceptance limit Observed error
  • Spirometry volume (FEV₁, FVC) −1.7 to +1.9% (limit ±3%)
  • Peak expiratory flow −4.2 to +2% (limit ±10%)
  • Oscillometry resistance +0.4 to +10% (limit ±20%)
  • FeNO at 15 ppb −4.1 to +4.8 ppb (limit ±5 ppb)
  • FeNO at 75–200 ppb −8.5 to +8.4% (limit ±10%)

All results fall within the acceptance limits. Each bar spans the full limit; the centre line is zero error.

A person breathing into the Respicorder mouthpiece, with the tablet on its stand showing a live breathing trace
USABILITY

Easy for clinical teams

15 of 15

lung function professionals performed all three tests after video training and onboarding1

50

respiratory clinicians and lung function professionals involved in co-developing and proving usability1,2

CLINICAL STUDY · AMSTERDAM UMC

The FABLE study

Adults with severe asthma starting a biologic, comparing Respicorder measurements with standard hospital spirometry, impulse oscillometry (IOS) and FeNO.3

84%
median adherence to twice-daily testing
1,830
test sessions
13
participants monitored
85
days median monitoring

ClinicalTrials.gov NCT06024707. Home monitoring is a research use and is not covered by the current UKCA intended purpose.

Working with research teams and pharma

Why use Respicorder data

  • Repeated FeNO, spirometry and IOS from one device
  • Treatment-response datasets for pharma partners

How we support studies

  • Evaluation units and demonstrations for research teams
  • Grant co-applications
  • Study design and training support

Where we are heading

  • Clinical studies and hospital-at-home pilots
  • Data integration
  • Co-evaluation of new use cases for objective lung data
Discuss a study

References

  1. Arete Medical Technologies. Respicorder Summative Usability Evaluation Report (AR-001182-UR), Amsterdam UMC and Medical Spectrum Twente, January 2026. Data on file.
  2. Formative usability study, Central London Community Healthcare NHS Trust. Data on file, Arete Medical Technologies.
  3. FABLE study, Amsterdam UMC: adults with severe asthma starting a biologic (research use). ClinicalTrials.gov NCT06024707.
  4. Bench verification reviewed by the UK Approved Body. Data on file, Arete Medical Technologies.
  5. Central London Community Healthcare NHS Trust clinical study. IRAS 332580.

See the Respicorder in your clinic?

Talk to our team about a demonstration, an evaluation unit or a quote, plan a research study, or download the clinician brochure.

Talk to our sales team Plan a research study Download the brochure (PDF)